5-34
Adjusting method:
Order Page Address Data
Procedure
1
Expose pattern A with the zoom
TELE end.
2
Adjust the inclination of the
camera so that the vertical black
line comes to the center of the
screen.
3
0
01
01
4
B
FF
08
Press PAUSE button.
5
Turn off the HOLD switch.
6
Adjust to the falling edge of the
waveform with vertical scale on
the oscilloscope.
(Oscilloscope is H period.)
7
Turn on the HOLD switch.
8
B
FF
09
Press PAUSE button. At this time,
measure the moving amount t1
(
µ
sec) of the falling edge of the
waveform.
9
Turn off the HOLD switch.
10
Obtain D
AD
’using the following
equation
(decimal calculation)
D
AD
’ = (4.0 / t1)
×
{1.01 / (Yaw
sensor sensitivity) }
×
94
(Note 1)
11
Raise D
AD
’ to a whole number,
convert it to a hexadecimal digit
and take this as D
AD
. (Note 2)
12
Turn on the HOLD switch.
13
F
AD
D
AD
Press PAUSE button.
14
B
FF
08
Press PAUSE button.
Note 1:
The Yaw sensor sensitivity (SE151 of CD-311 board) is
labeled only on the repair parts.
Note 2:
Refer to table 5-2-2. “Hexadecimal- decimal conversion
table”.
Processing after Completing Adjustment
Order Page Address Data
Procedure
1
0
01
00
2
Turn off the HOLD switch.
3
Check that the steady shot
operation is performed normally.
20. Steady shot adjustment
• Perform the steady shot adjustment only when replacing the
angular velocity sensor. When the microprocessor, circuit, etc.
malfunctions, do not perform this adjustment but check opera-
tions only.
• Record the sensitivity label of the angular velocity sensor (re-
pair part), including to which side of the board it was attached
to, etc. If it has been attached incorrectly, the image will move
up and down or to the left and right during steady shot opera-
tion. Be sure to take note of this.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03JA
Type B
ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
readjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Switch setting:
1) Steady shot (FRONT SW block) ........................... ON
20-1. Steady Shot Adjustment (1)
Mode
CAMERA
Subject
Pattern A
(1.5 m from the front of protection
glass)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope (H period)
Adjustment Page
F
Adjustment Address
AD
Fig. 5-1-20
White
White
Blac
k
A4 size (297 mm
×
210 mm)
Pattern A
Blac
k
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...