Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(10 cm from the front of the lens)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Shoot the Clear chart with
the zoom WIDE end.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
Perform “Data setting during
5
camera system adjustment”.
(Refer to page 5-14)
6
6
01
AD
Press PAUSE button (Note 2)
7
6
02
Check the data changes to
“01”.
Check the data.
8
6
AB
00 : Normal
01 to FF : Defective
Note 2:
The adjustment data will be automatically input to page:
F, address: 5A and 6C to 7F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
5
F1
00
3
D
63
00
Press PAUSE button.
Release the data setting
4
performed at step 5.
(Refer to page 5-14)
5
0
01
00
5.
F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
29 to 2C
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“F No. Standard Data Input” is available only once after
the power is turned on. Turn the power off, then on again
if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Shoot the Clear chart with
the zoom WIDE end.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
Perform “Data setting during
5
camera system adjustment”.
(Refer to page 5-14)
6
E
51
Note down the data.
7
E
51
FF
Press PAUSE button.
8
6
01
BB
Press PAUSE button.
(Note 3)
9
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 29 to 2C.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
E
51
Set data noted down at step 6,
and press PAUSE button.
3
5
F1
00
4
D
63
00
Press PAUSE button.
Release the data setting
5
performed at step 5.
(Refer to page 5-14)
6
0
01
00