5-15
1.
HALL Adjustment
For detecting the position of lens iris, adjust the HALL AMP gain
and offset.
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
2E, 2F, 34, 35
Specified Value
13 to 17 during IRIS OPEN
7B to 7F during IRIS CLOSE
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
The right 2 digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
5
6
94
15
6
6
95
7D
7
6
01
6D
Press PAUSE button. (Note 3)
8
6
02
Check the data changes to “01”.
9
6
01
00
Press PAUSE button.
Note 3:
The adjustment data will be automatically input to page:
F, address: 2E, 2F, 34 and 35.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
2
6
01
01
Press PAUSE button.
3
1
Check that the displayed data
(Note 2)
during IRIS OPEN satisfies
the specified value.
4
6
01
03
Press PAUSE button.
5
1
Check that the displayed data
(Note 2)during IRIS CLOSE
satisfies the specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
95
00
4
6
94
00
5
5
F1
00
6
D
63
00
Press PAUSE button.
7
Release the data setting
performed at step 4.
(Refer to page 5-14)
8
0
01
00