5-18
3-2.
Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
14 to 25
Adjusting method:
Order Page Address Data
Procedure
1
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away (subject with clear
contrast such as building,
etc.). (Nearby subjects less
than 500 m away should not
be in the screen)
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
5
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
6
6
01
13
Press PAUSE button.
7
Place the ND filter on the
lens so that the optimum
image is obtain.
8
6
01
29
Press PAUSE button. (Note 1)
9
6
02
Check the data changes to “01”.
Note 1:
The adjustment data will be automatically input to
page: F, address: 14 to 25.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
5
F1
00
3
D
63
00
Press PAUSE button.
4
Release the data setting
performed at step 5.
(Refer to page 5-14)
5
0
01
00
6
Perform“Flange Back Check”.
4.
Flange Back Check
Mode
CAMERA
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
5
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
6
Shoot the Siemens star with
the zoom TELE end.
7
Check that the lens is
focused.
8
6
2C
01
9
While observe the LCD
screen, change the zoom to
the WIDE end and check that
the lens is focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
5
F1
00
3
D
63
00
Press PAUSE button.
4
Release the data setting
performed at step 5.
(Refer to page 5-14)
5
0
01
00
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...