EXPRESS DAS
Installation and Operations Manual
76
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
9
Installation – OEU
The Optical Expansion Unit (OEU) is an optional component used for extending the EXPRESS DAS to
remote locations in a campus environment. Each OEU can be equipped with a maximum of two DOUs,
allowing the DAS to support an additional eight MRUs.
SOLiD technicians configure and label the equipment at the SOLiD facility prior to shipping. Note labeling
on all equipment. Remove each item from its packaging and inspect the hardware. Contact SOLiD
Support if the product is damaged.
9.1
Before you Begin
Before you begin this part of the installation process, make sure you have the following items. Those
items marked with an “O” ship with the unit. The installer will supply items marked with an “X.”
Item
Accessories
Tools
Status
Chassis rack mounting
M6 Screws (4 EA)
No.0 Screw driver (+)
X
Ground connection
M4 Screw (Electric Current/ 1EA)
No.0 Screw driver (+)
X
AWG #10~1 2 Cable
No.0 Screw driver (+)
Lug crimper
X
Connection with ODUs/ MRUs
Optic cable [SC/APC Type]
X
Power cable connection
DC -48V power cable (1 Pair)
[AWG #12, 2 meter, with 4.5 ø square
lugs at both ends]
No.0 Screw driver (+)
O
Table 9.1 – Accessories and Tools List for OEU Installation