EXPRESS DAS
Installation and Operations Manual
28
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
4.1.1
ODU Mechanical Specifications
Specification
Value
Downlink Input Power
-8dBm (VHF/UFH : -15dBm)
Uplink Output Power
-9dBm (VHF/UFH : -10dBm)
Nominal Impedance
50 ohm
Input Voltage
DC +9V
Voltage Standing Wave Ratio (VSWR)
1.8:1 at all in& out ports
Mounting Type
19” Rack Mounting (1U height)
Size (W x H x D) mm
482.6 (19") x 43.6 (1U) x 450
In & Output Port Type
SMA Female
Front Panel
LED Indicator
LD
Power on: Green, Alarm: Red
PD1 - PD4
Power on: Green, Alarm: Red
LED flickering: Communication Status
Total Max Weight
5.9 kg
Type Approval & Certification
UL(UL60950-1), FCC
EMC
FCC Part15 compliant
Power consumption
28.2 W
Table 4.1 – ODU Mechanical Specifications
4.1.2
ODU Environmental Data
Specification
Value
Environmental Condition
Indoor use only
Operating Temperature (°C)
-10° to +50°C
Operating Humidity
5 to 90% non-condensing
Table 4
.
2 – ODU Environmental Data