EXPRESS DAS
Installation and Operations Manual
52
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
6.1.2
OEU Mechanical Specifications
Specification
Value
Mounting Type
19” Rack Mounting. 2U height
Power Supply Voltage Range
-48V (DC: -42V ~ -56V)
Optic In & Out Port Type
SC/APC
Front Panel
LED Indicator
EWDM_LD
Normal: Green, Alarm: Red
EWDM_PD
Normal: Green, Alarm: Red
DOU1,2_LD
Normal: Green, Alarm: Red
DOU1,2_PD1
Normal: Green, Alarm: Red
DOU1,2_PD2
Normal: Green, Alarm: Red
DOU1,2_PD3
Normal: Green, Alarm: Red
DOU1,2_PD4
Normal: Green, Alarm: Red
STATUS_On
Normal: Green, Alarm: Red
STATUS_TXD1
Green flicker: ECPU send NMS Tx data to BIU
STATUS_RXD1
Green flicker: ECPU send NMS Tx data to BIU
STATUS_TXD2
Green flicker: ECPU send NMS Tx data to MRU/ARU
STATUS_RXD2
Green flicker: ECPU send NMS Tx data to MRU/ARU
ALM
Green: OEU system normal (no alarm)
RED: OEU System abnormal alarm
Maximum Power Consumption
40 W at full load
Total max weight
9.5kg (21 lb)
Type Approval & Certification
UL (UL60950-1), FCC
EMC
FCC Part15 compliant
Table 6
.
2 – OEU Mechanical Specifications
Содержание EXPRESS Single-Carrier DAS
Страница 10: ......