EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
9
2.7
Mechanical Specifications
Parameter
BIU
ODU
OEU
RF Connectors
4 SMA pairs (Tx, Rx)
per MDBU
2 SMA
-
External Alarm connector
(Dry contacts)
TB: 4pcs for output
TB: 3pcs for input
-
-
Interface ports
USB (B) type and Ethernet
1 USB (B) type
Fiber connector
-
8pcs, SC/APC for MRU
1 SC/APC for ODU
8 SC/APC for MRU
LED Alarm and
Status Indicator
MDBU Status
Power status
ALM status
MCPU
Power status
Tx Comm
Rx Comm
ALM status
MPSU
Power status
DC ALM status
DOU1 Status
LD status
PD1/2/3/4 status
DOU2 Status
LD status
PD1/2/3/4 status
EWDM Status
LD status
PD status
DOU1 Status
LD status
PD1/2/3/4 status
DOU2 Status
LD status
PD1/2/3/4 status
System status
Power status
TX1 Comm
RX1 Comm
TX2 Comm
RX2 Comm
ALM status
AC Power
-
-
DC Power
Normal range: -48 VDC
Operating range:
-40.8 - -57.6VDC
Provided by BIU
Power Consumption
SISO Mode: 162W
(Including 4 SISO ODUs)
MIMO Mode: 315W
(Including 4 SISO ODUs
and 4 MIMO ODUs)
28W
(Including 2 DOUs)
40W
(Including 2 DOUs)
Enclosure Dimensions
W x H x D mm
482.6 (19”) x 221.5 (5U) x
450
482.6 (19”) x 43.6 (1U)
x 450
482.6 (19”) x 88.1 (2U) x 450
Weight [Full Load]
26.2Kg
6Kg
9.6Kg
Table 2.1 – Mechanical Specifications for BIU, ODU, OEU
Содержание EXPRESS Single-Carrier DAS