EXPRESS DAS
Installation and Operations Manual
64
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
5- Once you have verified the unit is receiving power, turn off power to the BIU. You can power on the
system once you have connected the BTS or other RF source as described in the next sections.
8.3.1
BIU Power Consumption
The power supply provided for the BIU has factored in the max load for the system, but for your
information, the table below shows power consumption of the BIU. Keep in mind that the BIU also
supplies power to the ODU(s). Power consumption data for the ODU(s) are provided on page 74.
Part
Unit Name
Manufacturer
Product No.
Power Consumption (W)
SC_BIU_SISO
Common Part
Chassis
SC_BIU_C
-
7.2W
MCPU
SC_MCPU
4.8w
MPSU
SC_MPSU
-
MCDU
SC_MCDU
2.4W
SC_BIU_MIMO
Common Part
Chassis
SC_BIU_Chassis
-
9.6W
MCPU
SC_MCPU
4.8W
MPSU
SC_MPSU
-
MCDU
SC_MCDU
4.8W
MDBU
850C+1900P
SC_MDBU_850_1900
16W
AWS
SC_MDBU_700LTE_2100
16W
1900P
SC_MDBU_1900
9W
800i+900i
SC_MDBU_800_900
16W
Table 8
.
2 – BIU Power Consumption