Connecting the Add-‐on Unit to the MRU
1- Make all connections between the units according to the following figure and table. Make sure to
observe recommended torque values. Items marked with an “O” ship with the unit. The installer should
provide items marked “X.”
Figure 11.6 – Connecting the MRU to VHF/UHF AOR
No.
Item
Type
Torque
Status
1
Tx Cable
RF Interface Cable (SMA Male) – Qty 1
8~12kgf.cm
O
2
Rx Cable
RF Interface Cable (SMA Male) – Qty 1
8~12kgf.cm
O
3
Signal Cable
Data Interface Cable – Qty 1
-
O
4
Ground
AWG #10~12 Cable
Lug crimper
X
5
RX / SISO Antenna Cable RF Interface Cable (SMA Male) – Qty 1
8~12kgf.cm
X
6
TX / MIMO Antenna Cable RF Interface Cable (SMA Male) – Qty 1
8~12kgf.cm
X
7
Power Cable
AC power cable or DC -48V power cable – Qty 1 -
O
Table 11.4 – VHF/UHF AOR / MRU Connections