EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
75
8.6.3
Connecting ODU Optic Cabling
Each optical port on the DOUs can connect to an MRU using a single fiber optic cable with SC/APC
connectors. When connecting to an optional OEU, optical port 4 must be used from either DOU in ODU 1
or 2. ODU 3 and 4 cannot be used for connection to the OEU.
Figure 8
.
13 – SC/APC Fiber Terminations
1- Connect the fiber optic cable to the port(s) on the DOU(s).
8.7
Installing the DMS-‐600
The DAS Management System (DMS-600) fits in a standard 19-inch equipment rack and occupies 1U of
rack space. The unit has an internal power supply and requires standard 120-240V AC power.
1- Position the DMS-600 in the rack, making sure to leave 1U of space between the DMS-600 and the
uppermost ODU. This gap provides air circulation to help dissipate heat from the equipment.
2- Insert the M6 screws in the mounting holes and tighten the screws to secure the unit.
3- Connect the DMS-600 to the Ethernet port on the BIU using the supplied cable. Connect the unit to a
power source (typically a wall socket) using the supplied power cable.
4- Power on the DMS-600.
NOTE
: When purchasing, installing and maintaining the optic cables, make sure to follow the
manufacturer’s guidelines. Keep the fiber ends capped when not connected to prevent damage to the
fiber center pins. If fiber connectors seem dirty, you can clean them with alcohol.