EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
35
5.1.1
MRU/ARU Mechanical Specifications
Specification
Value
Uplink Input Power
-30 ~50dBm
Nominal Impedance
50 ohm
Power Supply Voltage Range
AC90 ~264V, Output Voltage: +25V
DC: -48V(-42 to -56V), Output DC: +25V
Voltage Standing Wave Ratio (VSWR)
1.6:1 at all in and out ports
Mounting Type
Wall Mounting & 19” Rack Mounting
In & Output Port Type
N Female & SMA Female
Front Panel
LED Indicator
ON
Power ON: Green, Alarm: Red
ALM
Power ON: Green / Power OFF: Gray
OPT
Normal: Green, Alarm: Red
TXD
Green Flickering
RXD
Green Flickering
Maximum Power Consumption
50W at full load
Type Approval & Certification
UL (UL60950-1), FCC
EMC
FCC Part 24 compliant
Table 5
.
1 – MRU/ARU Mechanical Specifications
5.1.2
MRU/ARU Environmental Data
Specification
Value
Environmental Condition & IP Rating
For indoor use, or an IP 65 / NEMA 4-rated enclosure is available for
outdoor installations.
Operating Temperature (°C)
-10° to +50°C
Operating Humidity
5 to 90% non-condensing
Table 5
.
2 – MRU/ARU Environmental Data