Installation and Operations Manual
60
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
8
Installation – Headend Equipment:
BIU, Power Supply, ODU, DMS-‐600
This chapter explains how to install and connect the DAS equipment that comprises the system’s
headend:
•
The Base-Station Interface Unit (BIU)
•
The DC power supply
•
The interface to the RF Source (BTS or BDA)
•
The Optical Drive Unit(s) (ODUs)
•
The DAS Management System (DMS-600)
SOLiD technicians configure and label the equipment at the SOLiD facility prior to shipping. Note labeling
on all equipment. Remove each item from its packaging and inspect the hardware. Contact SOLiD
Support if the product is damaged.
8.1
Before you Begin
Headend components are typically installed in a standard 19-inch rack according to these guidelines:
•
The BIU requires 5U of rack space and must have 1U of free space above and below to circulate
air and dissipate heat.
•
The DC Power Supply requires 1U of space. It typically mounts below the BIU.
•
The ODU components require 1U of space and can be stacked directly above one another. The
ODU(s) mount above the BIU in the rack.
•
The DMS-600 requires 1U of space but should have 1U of space above and below. The DMS-
600 typically mounts above the ODU(s).