EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
93
No.
Item
Type
Tool
Status
1
TRX CABLE 1
RF Interface Cable (SMA Male) (Qty: 1)
Spanner (8mm)
Torque 8~12kgf.cm
O
2
TRX CABLE 2
RF Interface Cable (SMA Male) (Qty: 1)
Spanner (8mm)
Torque 8~12kgf.cm
O
3
RX CABLE
RF Interface Cable (SMA Male) (Qty: 1)
Spanner (8mm)
Torque 8~12kgf.cm
O
4
TX CABLE
RF Interface Cable (SMA Male) (Qty: 1)
Spanner (8mm)
Torque 8~12kgf.cm
O
5
SIGNAL CABLE
Data Interface Cable (Qty: 1)
-
O
6
OPTIC CABLE
Optic cable [SC/APC]
-
X
7
POWER CABLE
AC power cable or
DC -48V power cable (Qty: 1)
-
O
8
POWER CABLE
AC power cable or
DC -48V power cable (Qty: 1)
-
O
9
GROUND
AWG #10~12 Cable
Lug crimper
X
10
GROUND
AWG #10~12 Cable
Lug crimper
X
11
ANTENNA
RF N-Type Plug
Spanner (20mm)
Torque 16.5~18.1kgf.cm
X
Table 10
.
3 – MRU/ARU Cable Connections
10.7
Connect Coaxial Cable and Antenna
Only the MRU has an antenna port. The ARU transmits its signal through RF cable connected to both the
MRU and ARU.
1- Before connecting the coaxial cable from the antenna to the MRU, check the Voltage Standing Wave
Ratio (VSWR) value to ensure it is within specification using a SiteMaster or DTF meter. Check if the
return loss is greater than 15dB or the VSWR value is less than 1.5:1. If it isn’t, you may need to redo the
RF connections on the cable.
2- Connect the coaxial cables to the antenna port of the MRU. Make sure the antenna connector is
tightened properly and free of dirt and the debris.
NOTE
: The antenna connected to the MRU is only for in-building use.