EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
111
12.5.5 Set MRU/ARU Parameters
1- Using the System Tree menu, select the MRU to configure.
2- Turn the relevant band on by selecting
ON
and pressing
SET
.
Figure 12.8 – Configuration Screen
3- Before turning on HPA, confirm that optic compensation has been performed. Click
On
TX HPA then
click
Set
.
4- Click
On
Tx OUTPUT AGS then click
Set
.
When this function is turned on, the system will set the MRU gain to the target level. While the AGS
function is being executed, the RESULT field will display PROCESSING and then shows the result:
•
Success: The AGS function is accomplished.
•
Not Operate OPTIC Comp: Optic compensation is not accomplished.
•
Lack of ATT: There is no attenuation available.
If optic compensation fails, return to previous section. Otherwise, move to next step.