EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
47
5.6
VHF/UHF AOR Components
Figure 5.8 – VHF/UHF AOR Internal View
Unit Name
Product No.
Description
1. VHF+UHF Remote Drive Unit
Included with
Cabinets:
SC_AC_150_450 and
SC_DC_150_450
Filter and high amplify downlink signals;
Filter and amplify uplink signals;
Remove other signals through Band Pass Filtering
(Note: BPF is not included with VHF+UHF module.)
2. System Interface Unit (SIU)
Included with cabinet.
Not field replaceable
Distributes power and signals of module
3. Add-on Remote (AOR)
Power Supply (AC or DC)
Included with Cabinet
For AC Unit:
Input AC 120V ; Output 27V, 9V, 6V
For DC Unit: Input DC -48V (-42--56V);
Output 27V, 9V, 6V
Table 5.14 – VHF/UHF AOR Components
5.6.1
AOR Remote Drive Unit (RDU)
When receiving downlink signals for each band from the MRU’s R_Optic module, the RDU filters out-of-
band signals and amplifies them with the high power amplifier. The unit also filters uplink signals received
through the uplink antenna and amplifies them before delivering the signals to the MRU’s R_Optic module.
Only the 150 VHF / 450UHF RDU is available for the AOR used with the EXPRESS system.
NOTE:
The 150 VHF / 450UHF RDU can also adjust gain, but it does not come fitted with a cavity
filter capability. External duplexers may be required but are not provided by SOLiD.”
Содержание EXPRESS Single-Carrier DAS