EXPRESS DAS
Installation and Operations Manual
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
91
10.5
Connect Optical Cabling
The MRU(s) connect to the optic modules in the headend ODU(s) (or optional OEUs) using fiber optic
cables with SC/APC connectors. SOLiD does not provide fiber optic cables with the DAS equipment. Only
the MRU has optical port; there is no optical port on the ARU.
When purchasing, installing and maintaining the optic cables, make sure to follow the manufacturer’s
guidelines. To prevent the fiber interface, make sure to keep it covered until connecting the fiber strand.
Keep the fiber ends capped when not connected to the equipment to prevent damage to the fiber center
pins. If fiber connectors collect dirt, you can clean using alcohol.
1- Insert the fiber into the optical port of the MRU. The bend radius of the fiber should not be less than
least 5 inches to minimize insertion loss and avoid damage to the optic cable.
During software commissioning, you will check to ensure the PD value of the optic module is within
acceptable range (+4--1dBm).
Figure 10
.
11 – Attaching Fiber Optic Cabling to the MRU