EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
Parameter
MRU
ARU
VHF/UHF AOR
RF Connectors
1 N-type
2SMA: optical
2SMA: RF
2SMA: optical
2SMA: RF
2 SMA Type female
External Alarm
Connector
(Dry contacts)
-
-
-
Serial Interface
1 USB (B) type
1 USB (B) type
-
Fiber Connector
1 SC/APC for ODU
-
-
-
LED Alarm and
Status Indicator
System status
Power status
Tx Comm
Rx Comm
ALM status
Opt status
System status
Power status
Tx Comm
Rx Comm
ALM status
-
AC Power
Normal Range: 120VAC
50/60Hz
Operating range
108-132VAC,50/60Hz
Same to left side
Normal Range: 120VAC
50/60Hz
Operating range
108~132VAC, 50/60Hz
DC Power
Normal: -48 VDC
Operating range:
-40.8 - -57.6VDC
Same to left side
Normal: -48 VDC
Operating range:
-42 to -56V DC
Power Consumption
50W for dual band
40W for dual band
78W C 93W for
VHF/UHF RDU
Enclosure Dimensions
(W x H x D mm)
300 x 200 x 258
300 x 200 x 258
482.6 (19“ rack) x 268.2 x 177
Weight (Full Load)
(Kg)
6.6
6.8
11
Table 2.2 – Mechanical Specifications for MRU, ARU, VHF/UHF AOR
2.8
Environmental Specifications
Parameter
BIU, ODU, OEU
MRU, ARU, VHF/UHF AOR
DMS-600
Operating Temperature (C)
-10 to +50°C
-10 to +50° C
-10 to +35°C
Operating Humidity, non-
condensing
-
5% to 90%
8 to 90%
Table 2.3 – Environmental Specifications