EXPRESS DAS
Installation and Operations Manual
104
EXPRESS DAS Installation and Operations Manual – Version 2.2 November 2013
12.3
Open Management Software and Run EasySET
1- In the browser URL address bar, enter the IP address: 192.168.58.1 or the URL
http://solid.local
The login screen appears.
2- Enter the username
ADMIN
and Password
1111
. (These values are set in the factory but you can
change them using the SETUP menu.)
The main screen appears.
3- The main screen shows information for your site.
Figure 12.2 – Management Software Home Screen
4- From the Command & Control tab, click the
EasySET
menu option.
On the EasySET screen, you will see these options:
•
Commission System
: Starts the auto commissioning routines. All system parameters are set to
the latest factory default values.
•
System Setup
: Enables changes to default values as necessary for specific installation
requirements.
5- Choose the BIU you want to commission. Click
Connect
.
The system writes a series of command lines showing status and verifying connection to the BIU.
6- Click
Commission System
.
The EasySET window appears.