background image

 

 

 

Zi de Kerandré 

– Rue Gutemberg – 56700 – HENNEBONT – FRANCE 

 

www.nke-marine-electronics.com

    

 

 

 

+33 297 365 685 

 
 

BOX Wi-Fi 

Product part number: 90-60-508-002 

 

 

 

 

 

USER MANUAL AND 

INSTALLATION GUIDE 

 

 

 

 

 

 

 

Summary of Contents for BOX Wi-Fi

Page 1: ...Zi de Kerandré Rue Gutemberg 56700 HENNEBONT FRANCE www nke marine electronics com 33 297 365 685 BOX Wi Fi Product part number 90 60 508 002 USER MANUAL AND INSTALLATION GUIDE ...

Page 2: ...ECTION 7 5 STATUS INDICATORS 7 6 USING THE INIT KEY 8 7 INSTALLATION 9 LIST OF ACCESSORIES 9 BEFORE INSTALLATION 9 MOUNTING THE BOX WIFI 9 CONNECTION TO THE TOPLINE BUS 9 NMEA INPUT SETUP 10 SETUP PROCEDURE 11 8 SET A WIFI CONNECTION TO A SMARTPHONE 11 9 TECHNICAL SPECIFICATIONS 13 10 DIAGRAMME DE FLUX 14 ...

Page 3: ...from an AIS receiver or any NMEA 183 source An auto baud rate detection algorithm allows reception of AIS and NMEA data at 4800 9600 19200 or 38400 bauds The baud rate is saved in the memory once 10 correct NMEA sentences have been received The AIS data flow received via the NMEA input is sent directly to the Wifi connection and the NMEA 183 output Data coming from the NMEA 183 device is sent once...

Page 4: ...XTE 18 SPEED OVER GROUND VTG RMC 19 COURSE OVER GROUND True VTG RMC 20 FORESTAY LOAD XDR 21 BEARING ORIGIN TO DESTINATION APA APB 22 B_PILOT APA APB XTE 23 YEAR MONTH ZDA RMC 24 F_HEADING HDG VHW HDM 25 F_APPARENT WIND ANGLE MWV VWR 26 LAT_DEGMIN GGA GLL RMC 27 LAT_MILMIN GGA GLL RMC 28 LON_DEGMIN GGA GLL RMC 29 LON_MILMIN GGA GLL RMC 30 SPEED TO WP WCV 31 TARGET SPEED KEP 32 NEXT TACK HEADING KEP...

Page 5: ...put is set to 38400 bauds and sends AIS data from the NMEA 183 input and Topline data converted to NMEA standard sentences to instruments from other manufacturers The following data is converted and sent via NMEA 183 depending on the relevant sensors being connected to the TOPLINE bus Canaux Topline XDR RSA DBT DPT VLW VHW MWV VWR VWT MWD MTW MMB HDG HDM HDT VTG ZDA GLL XTE RMB PNKEP 01 PNKEP 02 P...

Page 6: ...R MONTH X X HOUR DAY X X MIN SEC X X LAT_DEGMIN X LAT_MILMIN X LON_DEGMIN X LON_MILMIN X CROSS TRACK ERROR X X DISTANCE TO WP X BEARING TO WP X HEEL X PITCH X TARGET SPEED X NEXT TACK HEADING X OPTIMUM WIND ANGLE X TARGET VMG X TARGETPOLAR X CMG OPTIMUM ANGLE X TARGET CMG X VMG OPTIMUM ANGLE X TARGET VMG X CURRENT DIRECTION X SPEED CURRENT X CURRENT DIRECTION X SPEED CURRENT X MAN OVER BOARD X ...

Page 7: ...xxxxxx WPA 21xxxxxxxxxxx matching the serial number featured on the WiFi Box label sticked on the side of the box IP address 192 168 56 1 Port 50000 TCP UDP protocol TCP is a communication protocol which is based on connection with delivery validation and limits the use to one only host while UDP uses a simple transmission model allowing communication with several hosts simultaneously A DHCP serve...

Page 8: ... 1 sec to display the number of connected devices up to 5 1 device is indicated by the Topline led lighting red 2 devices by the Topline and NMEA Out 3 devices by the Topline NMEA Out NMEA In 4 devices by Topline NMEA Out NMEA In Wifi and 5 devices by all led indicators in red Press and hold 3 sec followed by OFF and ON to reset all NMEA interfaces Press and hold 3 sec will initialise the NMEA inp...

Page 9: ...in a location where there is no risk of submersion Mounting the Box WiFi Use Ø4mm screws WARNING The connection of the nke Box Wi Fi must be carried out before power to the unit is switched on Connection to the Topline Bus 1 Run the nke Box Wi Fi cable to the TOPLINE junction box in your system 2 Connect the bus cable in the junction box 3 Connect the NMEA and NMEA wires to your NMEA 183 device or...

Page 10: ...ing from an AIS receiver does not need NMEA input calibration It will be directly echoed on the Wi Fi and wired NMEA outputs The NMEA input must be set up to identify and save the NMEA sentences received from the connected instruments GPS PC etc NMEA channels are created and BLANC GND NOIR BLANC GND NOIR 12V GND NMEA NMEA NMEA NMEA init Power supply 12Vdc Junction box 90 60 417 DATA black 12VDC wh...

Page 11: ...ignals over 10 seconds and a long signal once the scan is completed Once the scan search is completed the unit will sound one signal per channel which has been created on the Topline bus WARNING If there is no NMEA data coming in this procedure gives a slave address to the nke Box Wi Fi In this case the Interface is considered as a slave unit by the master display 8 SET A WIFI CONNECTION TO A SMAR...

Page 12: ...available WiFi detected Type in the password WPA indicated on the WiFi Box label and press Connect Set the application you want to use nke Display in this example with the WiFi Box IP address 192 168 56 1 Port 50000 and the protocol UDP or TCP WARNING If your device is using a firewall check and make sure Port 50000 is available ...

Page 13: ...nput NMEA 183 automatic baud rate configuration from 4800 to 38400 bauds Direct reading of AIS data without input setup NMEA wired output NMEA 183 38400 bauds Wi Fi connection Wi Fi 802 11b g SSID NKE xxxxxx IP address 192 168 56 1 Port 50000 Protocol TCP UDP Environment IP54 protection against dust and water splashing Storage temperature 20 C to 60 C Operating temperature 10 C to 50 C Power cable...

Page 14: ...14 33 60 059 002 Box WI FI user manual 10 DIAGRAMME DE FLUX Init Wifi INPUT NMEA OUTPUT NMEA Topline Bus BOX Wifi NMEA Topline Topline NMEA ...

Page 15: ...15 33 60 059 002 Box WI FI user manual ...