Protection
Protection Module Configuration with IMx-M Manager
SKF Multilog On
-Line System IMx-M
2 - 113
User Manual
Identification
Figure 2 - 89.
Combined Measurement Identification - List of Types.
Type:
Currently permitted combined measurement types are the following:
Absolute Shaft Vibration
can be applied to all combined measurements 1
through 8. For detailed information refer to the measurement type Absolute
Shaft Vibration and the configuration example of a Absolute shaft vibration.
Piston Rod Drop XY (Average Mode)
can be applied to all combined
measurements 1 through 8. For detailed information refer to the
measurement type Piston Rod Drop and the configuration example of a Piston
rod drop.
Piston Rod Drop XY (Triggered Mode)
can be applied to all combined
measurements 1 through 8. For detailed information refer to the
measurement type Piston Rod Drop and the configuration example of a Piston
rod drop.
Complementary Differential Expansion
can be applied to all combined
measurements 1 through 8. For detailed information refer to the
measurement type Complementary differential expansion and the
configuration example of a Complementary differential expansion.
Temperature Difference
can be applied to combined measurements 5, 6, 7
and 8. For detailed information refer to the measurement type Temperature.
Every type should be given a name and comment to assist in identifying the combined
measurement.