![Siemens SIWAREX WP251 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538051.webp)
Commissioning
7.5 Service with the SIWATOOL program
SIWAREX WP251
Manual, 12/2015, A5E37203357A
51
7.5.4.2
Entering a known SIWAREX IP address
To establish a connection to a SIWAREX module, enter the IP address in SIWATOOL.
Under the menu item "Communication", select "Set Ethernet Configuration...". Enter the IP
address of the SIWAREX module in the following window. To activate the IP address and
establish a connection to the SIWAREX module, subsequently click on "Online".
7.5.4.3
Determining an unknown IP address
If the IP address of a connected SIWAREX module is unknown, it can be determined using
the program "Primary Setup Tool". The program is included in the configuration package
(Page 213).
Install the program "Primary Setup Tool". When started, the program can determine the
Siemens devices present in the network.
The MAC (Media Access Control) address can be read on the front of the SIWAREX
module. Every device has an MAC address which is unique worldwide.
The IP address can be determined from the identified MAC address. The Primary Setup Tool
also allows the IP address of a SIWAREX module to be set/changed.
Additional information on the Primary Setup Tool can be found in the associated manual.
7.5.4.4
Setting up a network
Several SIWAREX modules can be connected together in a network via a switch. Via the
network, you can use SIWATOOL to assign parameters to and start the various modules or
connect a common Operator Panel.
7.5.5
Online parameter assignment
To switch to online mode, connect the PC to the SIWAREX module using an Ethernet cable.
Set the IP address of the SIWAREX module in the communication menu.
You can change all parameters in the SIWAREX module in online mode. The message
window shows the current contents of the message buffer of the SIWAREX module. The
current process values are displayed in the "Online" column.
For test purposes, you can send various commands to the SIWAREX module. Differences
between the online/offline data are marked in red by SIWATOOL. This affects both the
associated data record and the individual parameter.
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...