![Siemens SIWAREX WP251 Скачать руководство пользователя страница 148](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538148.webp)
Scale parameters and functions
8.29 DR 32 Error messages
SIWAREX WP251
148
Manual, 12/2015, A5E37203357A
Variable
Note
Type
Length
(bytes)
RW De-
fault
Mi
n.
Max. Mod-
bus
regis-
ters
2116 Set point too large
In removal mode there is not
enough material in the container
at the start of dosing (gross < set
point)
Bit_7
1
r
0
-
-
3506
Reserve
Reserve
Bit_8
0
r
0
-
-
3506
Reserve
Reserve
Bit_9
0
r
0
-
-
3506
Reserve
Reserve
Bit_10
0
r
0
-
-
3506
Reserve
Reserve
Bit_11
0
r
0
-
-
3506
2096 Restore point set
Recovery point has been suc-
cessfully set
Bit_12
0
r
0
-
-
3506
2097 Restore point loaded Recovery point (or default param-
eters, if no recovery point) has
been successfully loaded
Bit_13
0
r
0
-
-
3506
2098 Standard parameters
loaded
Note for the user that the stand-
ard parameters were loaded
Bit_14
0
r
0
-
-
3506
2099 Factory settings load-
ed
Note for the user that the factory
settings were loaded
Bit_15
1
r
0
-
-
3506
5000 Data/command errors Group error
Bit_0
0
0
-
-
3507
6050 Unknown command
Issued command code is un-
known
Bit_1
0
0
-
-
3507
6051 Command not possi-
ble now
See "Additional information" for
more information
Bit_2
0
r
0
-
-
3507
6052 Service command
error
See "Additional information" for
more information
Bit_3
0
r
0
-
-
3507
6053 Calibration command
error
All calibration commands
Bit_4
0
r
0
-
-
3507
6054 Scale command error See "Additional information" for
more information
Bit_5
0
r
0
-
-
3507
6055 Weighing command
error
See "Additional information" for
more information
Bit_6
0
r
0
-
-
3507
6056 Memory command
error
Trace, log and log book com-
mands
Bit_7
1
r
0
-
-
3507
7050 Unknown data record Requested DR is unknown
Bit_8
0
r
0
-
-
3507
7051 Parameter input not
possible now
See "Additional information" for
more information
Bit_9
0
r
0
-
-
3507
7052 Parameter is write
protected and cannot be
changed
See "Additional information" for
more information
Bit_10
0
r
0
-
-
3507
7053 Error in calibration
parameter DR 3
See "Additional information" for
more information
Bit_11
0
r
0
-
-
3507
7054 Parameter error DR 5 See "Additional information" for
more information
Bit_12
0
r
0
-
-
3507
7055 Parameter error DR 6 See "Additional information" for
more information
Bit_13
0
r
0
-
-
3507
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...