![Siemens SIWAREX WP251 Скачать руководство пользователя страница 160](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538160.webp)
Scale parameters and functions
8.38 DR 48 date and time 2 (for Modbus)
SIWAREX WP251
160
Manual, 12/2015, A5E37203357A
Tag
Comments
Type
Length
(bytes)
Rw De-
fault
Min. Max.
Modbus
register
Device
Currently only logbook for
SecureDisplay SW
changes, corresponds to
entry "HMI"
CHAR[4] 4
r
" "
4412
String header for FW ver-
sion old
String header
UBYTE[2] 2
r
10,1
0
4414
FW version old
Old FW version, e.g.
V1.01.03
CHAR[10] 10
r
" "
4415
String header for FW ver-
sion new
String header
UBYTE[2] 2
r
10,1
0
4420
FW version new
New FW version, e.g.
V1.01.04
CHAR[10] 10
r
" "
4421
Checksum
Checksum of logbook
entry
USHORT 2
r
0
4426
Reserve
Reserve
USHORT 2
r
0
4427
8.38
DR 48 date and time 2 (for Modbus)
The SIWAREX module has its own hardware clock. The current date and the time can be set
and read using data record DR 48. The clock is buffered with a capacitor and can continue
operating for up to approximately 70 hours without supply voltage. If you are not using the
Modbus protocol, data record DR 8 is used for the date and time because it has the
SIMATIC DTL format directly.
Table 8- 39 Assignment of data record 48
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
registers
Data record
number
Contains no. of the data
record
USHORT
2
r
48
-
-
4500
Length
Data record length infor-
mation
USHORT
2
r
24
-
-
4501
Application
Information about which
application the data record
belongs to
USHORT
2
r
105
-
-
4502
Version
identifier
Current data record version
information
USHORT
2
r
1
1
65635
4503
Year
Year
USHORT
2
rw
2012
2012
2010
4504
Month
Month
USHORT
2
rw
1
1
12
4505
Day
Day in month
USHORT
2
rw
1
1
31
4506
Hour
Hour
USHORT
2
rw
0
0
23
4507
Minute
Minute
USHORT
2
rw
0
0
59
4508
Second
Second
USHORT
2
rw
0
0
59
4509
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...