Scale parameters and functions
8.26 DR 29 Configuration of technology messages
SIWAREX WP251
134
Manual, 12/2015, A5E37203357A
Variable
Note
Type
Length
(bytes)
RW
De-
fault
Min.
Max.
Modbus
registers
-
-
B16_6
0
rw
1
0
1
1816
-
-
B16_7
1
rw
1
0
1
1816
2101 Risk of overfilling Current configuration would
lead to overfilling during dosing
(is checked at multiple points
during dosing (e.g. after taring))
B16_8
0
rw
1
0
1
1816
2102 Coarse shut-off
point already exceed-
ed
The coarse shut-off point is
already exceeded before
switching on the coarse signal
B16_9
0
rw
1
0
1
1816
2103 No standstill
A required standstill did not
occur somewhere during dosing
B16_10 0
rw
1
0
1
1816
2104 CPU in "STOP" No stand-alone operation and
no CPU or CPU is not running
B16_11 0
rw
1
0
1
1816
2105 Set point too
small
The set point for the dosing is
too small in the current configu-
ration
B16_12 0
rw
1
0
1
1816
2106 Error fine weight Trailing weight, shut-off correc-
tion value and set point are not
compatible
B16_13 0
rw
1
0
1
1816
2107 Stop after toler-
ance error
Weighing cycle stopped after
tolerance error based on pa-
rameter assignment
B16_14 0
rw
1
0
1
1816
Reserved
-
B16_15 1
rw
1
0
1
1816
2109 Blocking time
"coarse" error
Blocking time coarse signal
After expiration of the blocking
time coarse signal, the coarse
shut-off point was already ex-
ceeded.
B17_0
0
rw
1
0
1
1817
2110 Blocking time
"fine" error
Blocking time fine signal viola-
tion After expiration of the
blocking time fine signal, the
fine shut-off point was already
exceeded.
B17_1
0
rw
1
0
1
1817
2111 Maximum weigh-
ing time exceeded
Maximum dosing time was
exceeded
B17_2
0
rw
1
0
1
1817
2112 Logging not
possible - no standstill
Logging conditions (standstill 2
and/or SecureDisplay not
shown) are not met, automatic
logging cannot be performed
B17_3
0
rw
1
0
1
1817
2113 Maximum empty-
ing time exceeded
Emptying monitoring time ex-
pired without achieving empty
state
B17_4
0
rw
1
0
1
1817
2114 Maximum correc-
tive action exceeded
Maximum corrective action
(defined in DR 24) was ex-
ceeded
B17_5
0
rw
1
0
1
1817
2115 Log error
Error while reading a log entry
(refresh DS 46 with Request ID
= 0)
B17_6
0
rw
1
0
1
1817
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...