Connection
6.9 Connection of Siebert display via RS485
SIWAREX WP251
Manual, 12/2015, A5E37203357A
37
6.9
Connection of Siebert display via RS485
A Siebert display S102 with the order no. S102-W6/14/0R-000/0B-SM can be connected to
the RS485 interface of the weighing module. Connect a 24 V DC supply to the Siebert
display, and connect the latter to the RS485 interface of the weighing module as shown in
the following diagram.
Image 6-6
Connection of Siebert display S102
The RS485 interface in DR 13 of the SIWAREX WP251 is set as follows:
●
Baud rate: 9 600 bit/s
●
Character parity: Even
●
Number of data bits: 8
●
Number of stop bits: 1
The S102 is set as follows:
Table 6- 7
Settings of Siebert display S102
Menu item
Setting
Meaning
1 Interface
485
RS485 interface
9 Station address
01
Address meaning:
Address Weight value
01
Verifiable weight
02
Total
03
Net
04
Tare
t Timeout
2
e.g. timeout after 2 seconds
C
0.0
No decimal point
F Segment test
----*
No segment test when switching on
8.8.8
Segment test when switching on
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...