Connection
6.10 Connection of the Ethernet interface
SIWAREX WP251
38
Manual, 12/2015, A5E37203357A
6.10
Connection of the Ethernet interface
An RJ45 connector is used for the connection.
The following devices can be connected to the Ethernet interface:
●
PC with SIWATOOL V7 service and commissioning program
●
Operator panels or other HMI devices with Ethernet and Modbus protocol TCP/IP
6.11
Activation of write protection
If a wire jumper is set between the module terminals P and PR, the parameter write
protection will be activated. With a few exceptions, when write protection is active the
parameters from data record 3 can no longer be edited and various service and calibration
commands can no longer be executed.
Table 6- 8
Activation of write protection
Labeling
Function
P
P terminal for activation of write protection
PR
PR terminal for activation of write protection
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...