![Siemens SIWAREX WP251 Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538117.webp)
Scale parameters and functions
8.22 DR 23 Material parameters
SIWAREX WP251
Manual, 12/2015, A5E37203357A
117
8.21.10
Number of not controlled weighings
This parameter defines how many cycles will not be checked for tolerance during continuous
operation in AWI mode. The first dosing cycle of the continuous operation is always checked
for tolerance, however. The discontinuation of the check(s) starts only after a dosing with
"Good" tolerance has been determined. Dosings that are not checked for tolerance are
classified as "GOOD" in the statistics (DR 39).
Note
Dosing cycles that cannot be checked
In unchecked cycles, there is no adjustment of the shut-off points by the proportional
controller.
Every dosing that is not checked is classified as "Good" in the statistics and the specified set
point (DS 20) is used in calculating the statistics.
8.21.11
Capture of weighings into statistics
This parameter defines, based on the tolerance evaluation, which dosing results are to be
included in the statistics calculation and which are not. The following options are available for
selection:
Function code Meaning
0 (default)
All dosings (with tolerance check) are included following "Dosing completed" in the
calculated statistics.
1
Dosings (with tolerance check) of "GOOD" class are included following "Dosing
completed" in the calculated statistics.
2
Dosings (with tolerance check) of "BAD" class are not included following "Dosing
completed" in the calculated statistics.
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...