![Siemens SIWAREX WP251 Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538121.webp)
Scale parameters and functions
8.23 DR 24 Controller and filter parameters
SIWAREX WP251
Manual, 12/2015, A5E37203357A
121
When the coarse signal is shut off, this may produce an overshoot that can be higher than
the fine shut-off point, which would cause the fine signal to be shut off too early. To prevent
this premature shut-off, the "Blocking time fine signal" can be defined in milliseconds (ms).
8.22.7
Shut-off correction weight
This parameter enables influences that occur during dosing (e.g. overpressure or
underpressure) to be taken into account in determining when the set point weight is reached.
The setting conforms to the "Parameter relation" setting and can thus be an absolute weight
or a percentage of the set point. The shut-off correction weight currently in effect is always
output in data record 31 in the weight unit.
8.23
DR 24 Controller and filter parameters
8.23.1
Overview
The parameters of the proportional controller and other filter parameters are defined in this
data record.
Table 8- 23 Assignment of data record 24
Variable
Note
Type
Length
(bytes)
RW
De-
fault
Min. Max.
Modbus
registers
Data record
number
Contains no. of the data record
USHORT
2
r
24
-
-
1694
Length
Data record length information
USHORT
2
r
56
-
-
1695
Application
Information on application to which
DR belongs
USHORT
2
r
105
-
-
1696
Version identifier
Current data record version infor-
mation
USHORT
2
r
1
1
65535
1697
0: Maximum corrective action and
controller deadband in % of set
point in DS 20
1: Specification as absolute values
USHORT 2
rw
0
0
0
1698
0: No controller
1: Proportional controller
USHORT 2
rw
1
0
0
1699
(Page 123) (%)
for proportional
controller
Control factor of proportional con-
troller
FLOAT
4
rw
30
> 0
0
1700
Reserve
Reserve
FLOAT
4
rw
0
0
0
1702
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...