![Siemens SIWAREX WP251 Скачать руководство пользователя страница 159](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538159.webp)
Scale parameters and functions
8.37 DR 47 Logbook
SIWAREX WP251
Manual, 12/2015, A5E37203357A
159
Designation
Data type
Length
Additional string
UBYTE
16
SEMICOLON
UBYTE
1
8.36.6
Date, time
The date and time of the selected log are displayed here.
8.37
DR 47 Logbook
The changes in the SecureDisplay software versions are recorded in the logbook. If the
SIWAREX has established communication with the SecureDisplay, SIWAREX checks
whether the software version of the SecureDisplay has changed. Changes are recorded in
the logbook. In this way, a more recent version of the SecureDisplay can also be used during
operation requiring calibration without the calibration being violated.
The logbook entries are in data record 47. Scrolling in the logbook is possible using
commands 881 to 883: → Command list (page
135). Calibratable reading of the logbook is
carried out using the SecureDisplay.
Table 8- 38 Assignment of data record 47
Tag
Comments
Type
Length
(bytes)
Rw De-
fault
Min. Max.
Modbus
register
Data record number
Contains no. of the data
record
USHORT
2
r
47
4392
Length
Data record length infor-
mation
USHORT
2
r
72
4393
Application
Information about which
application the data record
belongs to
USHORT
2
r
105
4394
Version identifier
Current data record ver-
sion information
USHORT
2
r
1
1
65635
4395
String header for oldest log
book ID
String header
UBYTE[2] 2
r
8,8
4396
Oldest log book ID
ID of first logbook entry
CHAR[8] 8
r
"0"
1
99999999 4397
String header of youngest
logbook ID
String header
UBYTE[2] 2
r
8,8
4401
Youngest logbook-ID
ID of last logbook entry
CHAR[8] 8
r
"0"
1
99999999 4402
String header for selected
logbook ID
String header
UBYTE[2] 2
r
8,8
4406
ID of the selected logbook
entry
ID of the selected logbook
entry
CHAR[8] 8
r
"0"
1
99999999 4407
String header for device
String header
UBYTE[2] 2
r
4,4
4411
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...