Commissioning FM 350-1
6.2 Procedure for assigning parameters
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
81
Table 6- 3
Check list for Measuring Modes
Working step
Options/Procedure
✓
Select encoder
A + B + N
A + B
A
5-V encoder with
symmetrical signals
Monitoring
None
≤200 kHz/≥2.5 μs
Max. count frequency
≤20 kHz/≥25 μs
Sinking output
24-V encoder with
asymmetrical signals
Encoder inputs
Sourcing output/push-pull
≤200 kHz/≥2.5 μs
Max. count frequency
≤20 kHz/≥25 μs
Sinking output
24-V encoder with pulse
train and direction signal
Encoder inputs
Sourcing output/push-pull
Normal
Count direction
Inverted
Set operating mode
Frequency measurement
Speed measurement
Period measurement
Update time
Pulses per encoder
revolution
1 μs
Resolution of period duration
1/16 μs
Gate control
SW gate
Configuring FM 350-1 in
HW Config
Gate control
HW gate