Operating Modes, parameters and commands
7.4 Measuring modes
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
153
7.4.7
Behavior of the Digital Outputs
Introduction
You can store an upper and a lower limit value for the frequency measurement, RPM
measurement or cycle duration measurement. This will be activated when digital output DO0
is exceeded. You can set these limit values and modify them via the load function. You can
use digital output DO1 as a normal digital output.
Enabling the Outputs
Before you can activate the outputs, you must first enable them by setting the appropriate
bits in the DB (see the chapter DB assignments (Page 169)). When you reset one of these
bits, the associated output is switched off immediately.
Table 7- 43 Enabling the Outputs
Output
... Is enabled by enable bit
DO0
CTRL_DO0
DO1
CTRL_DO1