Network and system integration
4.2 System configuration via PROFINET/PROFIBUS with CM
SIMATIC MV500
54
Operating Instructions, 06/2018, C79000-G8976-C494-01
4.2
System configuration via PROFINET/PROFIBUS with CM
①
Optical sensor or light barrier (for trigger signal)
②
Object with code
Figure 4-1
Example: System configuration via PROFINET IO/PROFIBUS DP-V1 with
communication module
System characteristics
●
The PROFINET/PROFIBUS connection is made via the CM interface of the optical reader
and a communication module.
●
PROFINET IO/PROFIBUS DP-V1 is connected to an S7 controller.
●
The optical reader is controlled via PROFINET IO/PROFIBUS DP-V1 using the Ident
profile block by the S7 controller.
●
The result is output via PROFINET IO/PROFIBUS DP-V1 to the S7 controller.
●
The optical reader is supplied with power via the communication module.
●
The optical reader is triggered either via digital I/O, S7 controller or via the built-in auto-
trigger function.
●
A PC/PG is connected via the Ethernet interface to allow adjustment of the device.
Содержание SIMATIC MV540 H
Страница 24: ...Description 1 7 Functional description SIMATIC MV500 24 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 194: ...Service and maintenance 10 3 Replacing a module SIMATIC MV500 194 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 232: ...Appendix A 3 Alternative user interfaces SIMATIC MV500 232 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 236: ...List of abbreviations SIMATIC MV500 236 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 238: ...Service Support SIMATIC MV500 238 Operating Instructions 06 2018 C79000 G8976 C494 01 ...