Mounting
5.3 Mounting with built-in ring light and EF lens
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
67
5.3
Mounting with built-in ring light and EF lens
Mounting the optical reader in conjunction with an EF lens (Electronic Focus Lens) is done in
two steps:
1.
Disassembling the built-in ring light
2.
Mounting the individual components
CAUTION
Disconnecting SIMATIC MV500 from the power supply
Make sure that the power supply is switched off when installing/uninstalling the devices as
well as the internal ring light, EF lens and micro SD adapter.
Disassembling the built-in ring light
Figure 5-3
Disassembling the built-in ring light
Follow the steps below to disassemble the built-in ring light:
1.
If necessary, remove the connection board
①
from the ring light
③
.
2.
Loosen the ring light from the ring light holder by unhooking the ring light
③
from the ring
light holder
②
.