Process interfacing via an automation system (PLC, PC)
9.3 Control with Ident profile
SIMATIC MV500
110
Operating Instructions, 06/2018, C79000-G8976-C494-01
Initialization
During initialization (INIT), the Ident profile automatically executes the "WRITE-CONFIG"
command. The parameter values of the "WRITE-CONFIG" command depend on whether the
Ident profile is used with or without a communications module.
WRITE-CONFIG
Table 9- 5
WRITE-CONFIG
CMD
OFFSET
BUFFER
LEN_DATA
CONFIG
TXREF
0x78
Offset in the
"TXREF" send
buffer
Length of the pa-
rameter data
•
0x01
≙
communica-
tion reset, no con-
figuration data
(LEN_DATA = 0)
•
0x03 ≙ communic
a-
tion reset, configu-
ration data to be
sent
Configuration data
to be sent
Structure of the configuration data attachment of WRITE-CONFIG
Table 9- 6
MV400 when CONFIG = 0x03; LEN_DATA = 0x10
Byte
1
2...5
6
7...8
9
10
11
12 ... 13 14
15
16
Value
0x04
0x00
0x0A
0x00
0x00
0x25
0x02
0x00
0x01
0x00
0x00 ... 0x0F
1)
1)
0x00: "INIT" without program selection
0x01 ... 0x0F: Number of the program to be started ("INIT" with program selection)
9.3.2
Control with MV commands via Ident profile
The optical reader is controlled by the "PHYSICAL WRITE" and "PHYSICAL READ"
commands. Chaining of commands is not supported.
An RFID system typically has a linear memory area for each transponder from which data
can be read or to which data can be written. The address space (in this case purely virtual) is
used in an optical reader to map certain MV commands (machine vision commands). In
addition, the data that is "written" to a specific address, for example, has a defined semantic
meaning.
This section explains which address space must be written to or which address must be read
from in order to cause specific behavior of the optical reader. The semantic meaning of the
read data or data to be written is also explained.
Содержание SIMATIC MV540 H
Страница 24: ...Description 1 7 Functional description SIMATIC MV500 24 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 194: ...Service and maintenance 10 3 Replacing a module SIMATIC MV500 194 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 232: ...Appendix A 3 Alternative user interfaces SIMATIC MV500 232 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 236: ...List of abbreviations SIMATIC MV500 236 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 238: ...Service Support SIMATIC MV500 238 Operating Instructions 06 2018 C79000 G8976 C494 01 ...