10.1.3
Error output of the read results
Table 10- 2 Error output of the read results
Message
number
Error message
Description
Corrective measures
1
Read error
(<Reason>)
The processing was not successful in
processing mode.
For possible causes, refer to "Read and
verification error messages" for the error
messages.
2
Filter error
(<Reason>)
The selected result string filtering
was not possible with the read code.
1.
Check whether the code just read is
correct.
2.
Check and, if necessary, correct the
selected result settings in the decoder
step in the "Result" tab.
3
Match error
(<Read result> !
<Match string>)
•
The configured comparison op-
tion was not found in the code to
be compared.
•
The string defined for training
does not match the current string
of the code or the plain text.
Check the selected result settings.
4
Format error
(<Reason>)
The configured format text does not
match the definition.
Check the selected settings.
You can find additional information in
"Overall result" in the online help.
The undefined formatting command is
issued as <reason>.
Note
Changing error texts
Note that the error messages in the WBM can be changed under "Application > Program >
Event > Error messages".
Содержание SIMATIC MV540 H
Страница 24: ...Description 1 7 Functional description SIMATIC MV500 24 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 194: ...Service and maintenance 10 3 Replacing a module SIMATIC MV500 194 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 232: ...Appendix A 3 Alternative user interfaces SIMATIC MV500 232 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 236: ...List of abbreviations SIMATIC MV500 236 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 238: ...Service Support SIMATIC MV500 238 Operating Instructions 06 2018 C79000 G8976 C494 01 ...