Image processing
3.3 Options for image acquisition and image processing
SIMATIC MV500
50
Operating Instructions, 06/2018, C79000-G8976-C494-01
Each evaluated program uses the cycle time limit specified in this program. The maximum
cycle time for the complete program sequence thus corresponds to the sum of the maximum
cycle times of the activated programs.
"Best read result" and "All read results" settings
In program sequence mode, as with the image acquisition option "Scan", you can use the
"Best read result" and "All read results" settings.
Differences between "Best read result" and "All read results" settings:
●
If you select "Best read result", a processing attempt is always made with all activated
programs. All successful evaluations are compared based on a selectable quality
criterion. The qualitatively best result is output.
●
If you select "All read results", a processing attempt is also made with all activated
programs. All successful evaluations are output.
Same image settings for all programs to be evaluated
If you want the same image settings to be used for all programs to be evaluated, you can
also activate the "Use 1st image" option. In this case, only one image acquisition is made for
each trigger. The settings of the program in the program sequence that has the lowest
number are used. The image acquired is then used for processing for all programs in the
program sequence.
3.3.5
Simple comparison for Track&Trace (MATCH mode/command)
Note
MATCH command not suitable for changing during production
The MATCH command is not suitable for switching during ongoing production.
The match string can already be pre-defined for non-complex match tasks when saving the
program. For a simple MATCH command, this can be done by a connected controller or a
PC.
MATCH is available via the interface for PROFINET (Ident), TCP, RS232 and
communication module. The MATCH command and its structure are described in detail in
the section "Process interfacing via an automation system (PLC, PC) (Page 103)".
Static match default when saving a program
For applications in which the match default is already known during commissioning, the
match can be defined and activated when the program is saved. You can enable match
mode for 1D/2D codes in the "Match" drop-down list from the "Program > Decoder >
MATCH" menu in the WBM.
Содержание SIMATIC MV540 H
Страница 24: ...Description 1 7 Functional description SIMATIC MV500 24 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 194: ...Service and maintenance 10 3 Replacing a module SIMATIC MV500 194 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 232: ...Appendix A 3 Alternative user interfaces SIMATIC MV500 232 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 236: ...List of abbreviations SIMATIC MV500 236 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 238: ...Service Support SIMATIC MV500 238 Operating Instructions 06 2018 C79000 G8976 C494 01 ...