Commissioning
7.4 Selecting connection alternatives
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
97
Operating the optical reader with a static IP address
Assign the network address manually in "Manual" IP mode. Enter the IP address and the
subnet mask to suit your network configuration and, if applicable, a gateway address.
NOTICE
Requirement for the IP address
The IP address of the optical reader must be in the same subnet as the IP address of the
communications partner.
Note
Gateway not required for direct connection
A gateway is not necessary for a direct connection between the optical reader and a PC/PG.
Operating an optical reader as a DHCP/DNS server
NOTICE
Possible faults when operating as a DHCP/DNS server
Note that operating the optical reader as a DHCP/DNS server can interfere with
communication in an existing network! Another DHCP/DNS server in the network must not
be enabled.
Note that the optical reader automatically operates as a DHCP/DNS server when
connected using the "CONNECT" button.
Operating the optical reader in PROFINET mode
In PROFINET mode, you can do the following with the optical reader:
●
Connect to the PC or the PG in your existing PROFINET IO network.
●
Integrate as a device in a PROFINET IO network.
●
Assign the IP configuration of the PROFINET IO controller.
Note
Parameter assignment of the IP configuration on the optical reader not possible
Note that in PROFINET mode, the IP address is automatically assigned via STEP 7. You
cannot manually adjust the IP address in WBM.
Содержание SIMATIC MV540 H
Страница 24: ...Description 1 7 Functional description SIMATIC MV500 24 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 194: ...Service and maintenance 10 3 Replacing a module SIMATIC MV500 194 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 232: ...Appendix A 3 Alternative user interfaces SIMATIC MV500 232 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 236: ...List of abbreviations SIMATIC MV500 236 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 238: ...Service Support SIMATIC MV500 238 Operating Instructions 06 2018 C79000 G8976 C494 01 ...