Preface
SIMATIC MV500
8
Operating Instructions, 06/2018, C79000-G8976-C494-01
Explanation of the table:
●
Authentication
Specifies whether authentication of the communication partner takes place.
●
Encryption
Specifies whether the transfer is encrypted.
NOTICE
Opening ports by changing the parameter settings
Make sure that port "TCP/8765" is open when enabling the "Archiving/MMI" parameter.
Make sure that port "TCP/8000" is open when enabling the "TCP" parameter.
You can find additional information about these parameters in the section "Communication
> Interfaces" of the WBM online help.