Service and maintenance
10.1 Error and diagnostics messages
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
183
Error code
(%c)
Error message
(%s)
Description
4708
Mean light outside of range in step n: Cycle time
limit of the automatic exposure control reached
The average brightness needed for ISO/IEC 29158 is
outside the valid range (see Error code 4709).
The automatic exposure control was unsuccessful
because the necessary decodings could not be com-
pleted within the time limit.
To resolve this error:
•
Reduce the exposure ROI of the program.
•
Increase the time limit of the exposure control.
•
Also ensure that the code is completely within the
exposure ROI until conclusion of the image acqui-
sition process.
4709
Mean light outside of range in step n
The average brightness needed for ISO/IEC 29158 is
outside the valid range (70% to 86%) in step #n.
4710
Verification failed in step n: Data Matrix ECC200
required
Verification requires a data matrix code according to
ECC200 specification (only for verification according
to ISO/IEC 15415 or ISO/IEC 29158).
4711
Verification failed in step n: Aperture too small
The cell size of the data matrix code in step #n is too
large for the configured aperture (only for verification
according to ISO/IEC 15415).
4712
Verification failed in step n: Aperture too large
The cell size of the data matrix code in step #n is too
small for the configured aperture (only for verification
according to ISO/IEC 15415).
4713
Verification failed in step n: Not enough space
around the Data Matrix
The quiet zone around the data matrix contained in
the image is too small. For verification, a quiet zone of
at least the size of two cells is required (only for verifi-
cation according to ISO/IEC 15415 or 29158).
4714
Verification failed in step n: RDA could not find
the horizontal timing pattern
The reference decoding according to
ISO/IEC 16022:2006 signals an error when searching
for the horizontal timing pattern (only for verification
according to ISO/IEC 15415 or ISO/IEC 29158).
4715
Verification failed in step n: RDA could not find
the vertical timing pattern
The reference decoding according to
ISO/IEC 16022:2006 signals an error when searching
for the vertical timing pattern (only for verification
according to ISO/IEC 15415 or ISO/IEC 29158).
4716
Verification failed in step n: RDA found an incor-
rect number of rows and columns
The reference decoding according to
ISO/IEC 16022:2006 signals an error when determin-
ing the number of rows or columns (only for verifica-
tion according to ISO/IEC 15415 or ISO/IEC 29158).
4717
Verification failed in step n: RDA could not locate
the finder pattern
The reference decoding according to
ISO/IEC 16022:2006 signals an error when searching
for the finder pattern (only for verification according to
ISO/IEC 15415 or ISO/IEC 29158).
4719
Verification failed in step n: RDA error correction
failed
The reference decoding according to
ISO/IEC 16022:2006 signals an error when determin-
ing the error correction (only for verification according
to ISO/IEC 15415 or ISO/IEC 29158).
4720
Verification failed in step n: Number of Data Ma-
trix rows/columns is too high
The maximum supported code size for verification
according to ISO/IEC 15415 or ISO/IEC 29158 is
104x104 cells.
Содержание SIMATIC MV540 H
Страница 24: ...Description 1 7 Functional description SIMATIC MV500 24 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 194: ...Service and maintenance 10 3 Replacing a module SIMATIC MV500 194 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 232: ...Appendix A 3 Alternative user interfaces SIMATIC MV500 232 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 236: ...List of abbreviations SIMATIC MV500 236 Operating Instructions 06 2018 C79000 G8976 C494 01 ...
Страница 238: ...Service Support SIMATIC MV500 238 Operating Instructions 06 2018 C79000 G8976 C494 01 ...