Operating the Sensor
36
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
Setting
item
Bank Setting value/
default value
General description
Alarm limit
Y
Set the number of values (measured values to the right) to maintain when an alarm occurs.
When you specify this setting, the specified number of values immediately before the alarm (to the
right) will be maintained.
If alarms occur repeatedly such that the set number of values is exceeded, an alarm (measured value
7FFF) is triggered.
0 to 14/HOLD
[
6
]
[Unit: Number of values] * HOLD: Alarm state is not entered.
Smoothing
Y
This function averages the profile in the horizontal (X-axis) direction to make the waveform smoother.
[Unit: Number of measurements]
1
Averaging will not be performed.
2
4
8
16
32
64
128
Correct
method
Y
Select the correction method.
To use this function, you have to perform master image registration. Also, when you change this setting,
you have to update the master image.
-
Correction will not be performed.
→
Position correction will be performed on the basis of the left side.
←
Position correction will be performed on the basis of the right side.
↑→
Height correction will be performed, and then position correction (left side)
will be performed.
↑←
Height correction will be performed, and then position correction (right side)
will be performed.
↑
Height correction will be performed.
H correct
Y
The position of the area at the specified height will be corrected by the difference between the master
image and the measured profile.
To use this function, you have to perform master image registration. Also, when you change this setting,
you have to update the master image.
-28000 to +28000
[
0
]
[Unit: X coordinate] * You can set this value in steps of 2.
V correct
Y
The height of the area at the specified position will be corrected by the difference between the master
image and the measured profile.
To use this function, you have to perform master image registration. Also, when you change this setting,
you have to update the master image.
The condition to enable this function is: Correct method:
↑→
,
↑←
, or
↑
.
-15000 to +14998
[
-6500
]
[Unit: Y coordinate] * You can set this value in steps of 2.
Tilt correct
Y
The profile tilt will be corrected so that the two specified points become level with each other.
ON/