Setup and Measurement Procedures
20
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
4.2
Quick Setup
4.2.1
Basic Measurement Settings
You can take basic measurements simply by setting the following three
items. Configure the settings from the sensor or from the PRO2-Navigator
setup software.
• Shutter time
• Area
• Output conditions
Reference: For the actual screens and for information on the operations,
see the following pages.
Configuring settings from the sensor
Using PRO2-Navigator
“6.3 PRO2-Navigator Screen and Operating.”
1. Set the shutter time
Position the measurement target, and then perform automatic adjustment.
The optimum shutter time will be set.
2. Set the area
Use the area setting to specify what part you will measure and how that
part will be measured.
1. Measurement area
• Set what part within the measurement range will be measured.
The set area must intersect the profile (the sectional waveform).
2. Measurement function
• Set the measurement function. You can select from functions
such as height and width.
Reference: For details on the area settings, see “7.6 Area Settings.”
3. Set the output conditions
Configure the settings related to the output of the measured results.
First, specify the judgment and output target area.
• Output target
Select the target area (area 1 to area 4 and calculation 1 and
calculation 2).
1. Measurement output
The product judges whether the measurement is a pass or a fail,
and then outputs the result.
• Upper limit/lower limit
2. Analog current output (4 to 20 mA)
• 4 mA/20 mA
Set the lower and upper limits of the analog output range.