Functions
1shot2
The output turns on only for the specified output time when the measured
value is outside the threshold range.
Since output is performed only when the measured value is outside the
threshold range, output does not turn on when there are continuous out of
range values.
Output time
When using the “1shot,” “OnDelay,” or “Strobe” setting, specify the
output time.
7.8.4
Offset/Offset Value
When offset input is received, values are added to or subtracted from the
current display value so that it becomes the value set with “Offset value.”
The offset value can be set for each output.
When the offset operation is executed, values are added to or subtracted
from the measured value of (1) the area that the output is referencing
or (2) a calculation. (The parts indicated with dotted lines in the following
figure.)
1 2
4
3
1 2
1 2 3
Area Area Area Area
Calc Calc
Out
Out
Out
Area
Calculation
Output
[Setting target:] Outputs 1 to 3
ON
OFF
ON
OFF
ON
OFF
Upper limit
Output time
Output