Functions
94
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
Tilt method
Corrects the installation tilt and the tilt of the measurement target object.
The profile tilt will be corrected so that the height correction reference
position and the tilt correction reference position become level with each
other. If an alarm occurs in either of the reference positions, the tilt correc-
tion will not be performed. In master image registration, the profile after tilt
correction is performed is registered. In tilt correction, the shape
of the profile is corrected. The area position is not corrected.
1. Set the height correction reference position.
This reference position is also used in tilt correction.
(The dotted line is the height correction reference position.)
2. Set the tilt correction reference position.
Set the reference position to the same height as the height correction
reference position. (The dotted line indicated by the arrow is the tilt
correction reference position.)
Before Correction
After Correction
3. The correction is performed so that the two reference position
heights become the same.
The tilt correction is performed so that the two reference position
heights become the same.