Specifications
134
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
9
Specifications
9.1
Specifications
Model
PRO2-N100B25A1 (6052874)
PRO2-P100B25A1 (6052873)
Measurement range
100 ± 25 mm
Field of view (at measuring dis-
tance)
17 mm (at 75 mm), 27 mm (at 125 mm)
Light source
Red laser, wavelength: 655 nm, max. output: 1 mW
Laser class
IEC/JIS
Class2
FDA
CLASS II
Spot size
*1
0.3 × 32 mm
Linearity
Z axis
0.1% of F.S. (50 μm)
Resolution
*2
Z axis
2 μm
Resolution
*3
X axis
25 μm
Response time
Typical value: 5 ms (when measuring the whole view in “Hi-res” mode),
max. speed: 0.5 ms
Display
Dot matrix display
LEDs
Power indicator (green), laser emission indicator (green)
External input
Selectable from bank, trigger, hold, reset, laser emission stop, and offset
Control output
3 NPN open collector outputs, max.
100 mA/30 VDC
(max. residual voltage: 1.8 V)
3 PNP open collector outputs, max.
100 mA/30 VDC
(max. residual voltage: 1.8 V)
Analog output
4 to 20 mA, out of measurement range: 24 mA (max. load impedance: 300 Ω)
Communication interface
RS-485 half duplex (9.6 kbps to 4.0 Mbps)
Temperature drift (typical example)
0.05% of F.S./°C
Power supply voltage
12 to 24 VDC (+10%, -5%, including ripple)
Current consumption
*4
Max. 180 mA
Protection category
IP67
Operating temperature/humidity
–10 to +40°C/35 to 85%RH (no condensation or freezing)
Storage temperature/humidity
–20 to +60°C/35 to 85%RH (no condensation or freezing)
Operating illuminance
Sunlight: 10000 lx or less, high-frequency lamp: 3000 lx or less
Vibration resistance
10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions
Shock resistance
Approximately 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions
Material
Housing: die-cast zinc and PC,
laser emitter and receiver covers: glass
Weight
Approximately 300 g
*1 Defined with center strength 1/e2 (13.5%) at the center of measurement range. The sensor may be affected when leak light other than that
of the specified spot size is present and when there is a highly reflective object close to the detection area.
*2 Average height measurement of a white workpiece with a center width of 5 mm, smoothing performed 8 times,
moving average performed 32 times (with the default settings)
*
3 With a measurement distance of 75 mm
*4 Power supply voltage: 24 VDC not including the control output load current and including the analog output