Operating the Sensor
30
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
5.2.4
Other
Setting
item
Bank Setting value/
default value
General description
Bank
switch
N
Select how to change between banks.
In/Para
Sensor operations or the input terminals will be used to change between banks.
Comm
Communication (including PRO2-Navigator) will be used to change between banks.
Bank
N
Change the bank. The display details vary depending on the settings of the input terminals.
The bank is determined by the details of this setting and the status of the input terminals.
The condition to enable this function is: Bank switch: In/Para.
Input terminal
settings
IN1: BANK1
IN2: BANK2
IN3: BANK3
—
You cannot switch the bank from
the sensor.
Input terminal
settings
Reset
IN2: BANK2
IN3: BANK3
1, 3, 5, 7
The bank is changed to number 1, 3, 5, or 7.
2, 4, 6, 8
The bank is changed to number 2, 4, 6, or 8.
Input terminal
settings
IN1: Reset
IN2: Hold
IN3: BANK3
1, 5
The bank is changed to number 1 or 5.
2, 6
The bank is changed to number 2 or 6.
3, 7
The bank is changed to number 3 or 7.
4, 8
The bank is changed to number 4 or 8.
Input terminal
settings
IN1: BANK1
IN2: BANK2
IN3: Trigger
1, 2, 3, 4
The bank is changed to number 1, 2, 3, or 4.
5, 6, 7, 8
The bank is changed to number 5, 6, 7, or 8.
Input terminal
settings
IN1: Reset
IN2: BANK2
IN3: Trigger
1, 3
The bank is changed to number 1 or 3.
2, 4
The bank is changed to number 2 or 4.
5, 7
The bank is changed to number 5 or 7.
6, 8
The bank is changed to number 6 or 8.
Input terminal
settings
IN1: BANK1
IN2: Hold
IN3: Trigger
1, 2
The bank is changed to number 1 or 2.
3, 4
The bank is changed to number 3 or 4.