INSTRUCTIONS
HIGH BAY SERIES
RAB Lighting 1s committed to creating high quality, affordable well designed and energy efficient LED l1ght1ng and controls that make 1t easy for electricians to install
and end users to save energy We'd love to hear your comments Please call the Marketing Department at 888 RAB 1000 or email market1ng@rablighting com
HID-XXX-V-EX39-8XX-BYP-HB
RAB sensors MW-5 (Microwave) and PIR-S
(Infrared) are optional accessories for the High Bay
series. They perform as regular lamps when no
sensor is inserted. Please note: RAB lamps will not
work with other brand sensors.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING LED HID BULBS. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB LED HID Bulbs must be wired in accordance with the National Electrical Code and all applicable codes.Proper
grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
WARNINGS:
• Main applications include for use in high bay and other suitable light fixtures.
• Operating temperature:-30
°
C to 60
°
C (-22
°
F to 140
°
F).
• These LED Lamps require all ballasts, capacitors, and ignitors to be bypassed or removed. Do not operate lamps on
existing ballasts.
• This product is not dimmable. Do not use with dimmers.
• This device is not intended for use with emergency exits.
• For use in enclosed fixtures.
• Before installation make certain the AC power to the fixture is off.
• Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED
retrofit kit. Check for enclosed wiring and components.
• Risk of fire or electric shock. LED Retrofit lamp installation requires knowledge of luminaires electrical systems. If not
qualified, do not attempt installation. Contact a qualified electrician.
• Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
• Installers should not disconnect existing wires from lampholder terminals to make new connections at lamp holder
terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical
connections to lamp holder lead wires by employing applicable connectors.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
• Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in
the photographs or drawings and where the input rating of the retrofit kit does not exceed the input rating of the
luminaire.
• Use only with a portable luminaire that is provided with a shade.
• Added weight of the device may cause instability of a free-standing portable luminaire.
• THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
INSTALLATION INSTRUCTION
Burning positions:
Base up
You must use the safety cable to
tighten the lamps in case th
ey
fall
down due to an old socket.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.