8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
131
Serial Communication
Function
Set or
acquire
Send
or
reply
Length Command
(hex)
Data string
Parameter
Trig action
Set
Send
1
2006
000a
a: Trigger method
a
Setting value
a
Setting value
0
Cont
2
Count
1
1shot
Reply
0
—
Acquire Send
0
2007
—
Reply
1
000a
Trig count
Set
Send
1
2012
aaaa
aaaa: Number of triggers
1 to 4095 [number of times]
Reply
0
—
Acquire Send
0
2013
—
Reply
1
aaaa
Inp filter
Set
Send
1
c003
00aa
aa: Input filter time
1 to 255 [×5 μs]
Reply
0
—
Acquire Send
0
c004
—
Reply
1
00aa
Trig delay
Set
Send
1
2014
aaaa
aaa: Trigger delay time
1 to 4095 [×5 ms]
Reply
0
—
Acquire Send
0
2015
—
Reply
1
aaaa
Offset
target
Set
Send
1
c007
000a
• a: Offset target
a
Setting value
a
Setting value
0
Indivi
3
OUT2
1
All
4
OUT3
2
OUT1
Reply
0
—
Acquire Send
0
c008
—
Reply
1
000a
8.5.9
Storage Settings
Function
Set or
acquire
Send
or
reply
Length Command
(hex)
Data string
Parameter
Storage
Set
Send
1
c00e
000a
a: Target data
a
Setting value a
Setting value
0
OFF
2
Profile
1
Measure
Reply
0
—
Acquire Send
0
c00f
—
Reply
1
000a
No.of Data
Set
Send
1
c012
aaaa
aaaa: Number of saved data items
Measured value: 1 to 65535
Profile: 1 to 8000
Reply
0
—
Acquire Send
0
c013
—
Reply
1
aaaa