8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
93
Functions
Correct method
Sets whether to use position and height corrections and the order to use
these corrections in.
•
-
:
Correction will not be performed.
•
→
:
Position correction (left side) will be performed.
•
←
:
Position correction (right side) will be performed.
•
↑→
:
Height correction will be performed, and then position
correction (left side) will be performed.
•
↑←
:
Height correction will be performed, and then position
correction (right side) will be performed.
•
↑
:
Height correction will be performed.
The actual correction operation behaves as shown below.
The “
↑→
” correction operation is explained here.
1. Set the reference position and height.
Set the reference position and height, corresponding to the master
image, at which correction will be performed.
2. Perform measurements, and then detect the height
and position correction amounts.
Detect the height and position correction amounts from the master
image and the measured profile.
3. Correct and measure the area.
Move the area according to the correction, and then measure the area.