8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
91
Functions
H correct
Sets the threshold. If the profile exceeds the threshold, the waveform
will be moved horizontally to the reference position.
Master image
Area
1. Set the reference height.
Set the reference height, corresponding to the master image, where
correction will be performed.
The position farthest to the right or left that crosses this height will be the
correction reference position. (In the figure to the right, the reference is the
left position.)
Set the reference to a height that will definitely be crossed by the master
image and by the profile during measurement.
Profile
2. Perform measurements.
Measure the points on the measured profile that have exceeded the
threshold.
3. Perform corrections.
The area will be moved by just the amount that the measured waveform
and master image positions are shifted.
Tips: • If you specify a height for which there is no measured data in the master
image, the position correction is not performed.
•
If there is no measured data at the specified height during measurement,
measurement is performed without correction.
•
Perform position correction for convex profiles like those described above.
Position correction may not operate correctly for concave surfaces.
•
For level differences, whether the correction will be performed appropri
-
ately varies depending on the correction direction.
○: The correction can be
performed appropriately.
×: The correction may not be
performed appropriately.